Mcquay model number tonnage

The PFH series are equipped with two compressors operating in parallel on a single evaporator and<br />. condenser. Model PJH series are the equivalent double bundle heat recovery units.<br />. The chillers use refrigerant R-134a to reduce the size and weight of the package compared to negative<br />.

Mcquay model number tonnage. Manufacturer McQuay. Tonnage 500. Air or Water Water Cooled. Refrigerant R-134a. Voltage 460. Phase 3. Hz 60. Model Number WME0501SBSNA. Serial Number STNU180500021.

View and Download McQuay Vision CA Series installation and maintenance manual online. Vision CA Series air handlers pdf manual download. ... Air handler models oac/oah …

Look under the hood and see pictures of other car makes and models on the HowStuffWorks Auto Channel's Other Makes and Models section. See how other car makes and models stack up. ...Most efficient full load and part load operation, up to COP 3.6. New generation screw compressor with high operation efficiency. Largest capacity air-cooled screw chiller, up to 450 tons. Small footprint to optimize space and reduce installation costs. Quietest operation with sound pressure levels as low as 76 dBA with no attenuation.How to determine the date of production/manufacture or age of Daikin® brand HVAC Systems. The industry average service design life for most forced air furnaces is 15-20 years, and the industry average service …Supply McQuay, central air conditioning repair parts MT3022 inventory Numbers M332608311 control module,Refrigeration Fittings Manufacturers &Refrigeration Fittings Suppliers Directory - Find a Others Manufacturer and Supplier. ... McQuay . Model Number: MT3022. Place of Origin: USA. Packaging & Delivery. ... EPROM, pump frequency conversion ...Available from 600 to 2500 tons, dual compressor chillers offer excellent full-load and part-load performance for increased energy savings. This industrial chiller occupies less floor space than having multiple single compressor chillers, while delivering the equivalent combined capacities. Using R-134a or R-513A refrigerant, these chillers ...

Obsolete Brand (1994) How to determine the date of production/manufacture or age of Snyder General® HVAC Systems. The date of production/manufacture or age of Snyder General® HVAC equipment can be determined from the serial number located on the data plate.How Do I Read My AC Model Number? Let's look at a Trane brand air conditioner as an example. Capacity: Trane has used a number of different methods for encoding capacity information in the model number. It is commonly found in the first three digits – sometimes as BTUs and sometimes as tons. Example: SPCC-B504-A = 5.0 ton, or; TWS748A ...This model is intended for new construction or the replacement of Climate Master 8S water source heat pumps. Islandaire "The Perfect Fit" units are designed to exactly replace the original, existing chassis! ... This appliance is intended for new construction or replacement of McQuay and Singer LM water source heat pumps. Islandaire "The ...McQuay 61149604 HEATER ELECTRIC WIRE. Our Price: C$ 172.78. My Price: Mfr Part #: 61149604. PT #: MCQ061149604. Quantity Available: 0. Out of Stock, backorders usually ship in 10-12 days. Add to cart. Add to My Parts. McQuay offers air-cooled chillers from 10 through 425 tons (35 – 1500 kW). This manual covers two varieties of the scroll compressor, air-cooled Global Chiller Line: AGZ 030AS through AGZ 065AS, Packaged Air-Cooled Chillers AGZ 030AM through AGZ 050AM, Air-Cooled with Remote Evaporator. Nomenclature A G Z - XXX A S Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the data plate below indicates the system is 3 tons.Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongA ton of air conditioning equals 12,000 BTU so, for the model number 4AC18LT 24 P, 24 divided by 12 equals 2 tons. Another example is RHP13A48F, which is 4 tons. And this example is 2-1/2 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons.

View and Download McQuay RAH 047C installation and maintenance manual online. Applied Rooftop Systems Air Handler. ... Page 1 Group: Applied Air Systems ™ Part Number: IM 987 Air Handler Date: May 2009 RAH 047C - 077C, 12,000 to 50,000 cfm RDS 800C ... provide the model number, serial number, and unit part number of the unit as stamped on the ...McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors ofIndustry-LeadingTechnologies. To meet and exceed demanding building performance criteria, our rooftop systems integrate advanced HVAC technologies including: Variable speed inverter compressor. Variable speed heat pump. Direct-drive fans with variable speed ECM or VFD motors. Energy recovery wheel. Outdoor air monitor. Modulating hot gas …Figure 1: Magnetic Bearing Compressor Shaft. system replaces conventional oil lubricated bearings and a direct drive motor eliminates the need for a lubricated gear box. The compressor shaft, shown in Figure 1, levitates on a magnetic cushion and is the compressor's only major moving component.All McQuay low and medium pressure central station air handling units (sizes 114 through 172) have factory installed, internally mounted motors and drives .. This means that ex­ …

Po174 chevy silverado.

Putting the IQin IAQ. At Daikin, we're driven by a simple belief: organizations are at their best when their air is at their best. Our approach to groundbreaking R&D, precision engineering, and industry-leading solutions brings a level of intelligence to the HVAC industry that's nothing short of a breath of fresh air.Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter.Part Number: 331499601 Effective: October 2011 Supersedes: August 2011 Magnitude™ Magnetic Bearing Centrifugal Chiller . Model WME 0500, WME 0700 . 400 to 700 tons (1400 to 2461 kW) ... Daikin McQuay Magnitude model WME frictionless centrifugal chillers are complete, self-contained,Buick car models come in all shapes and price ranges. See pictures and learn about the specs, features and history of Buick car models. Advertisement Buick models come in all shape...

Application Capacity. Application Capacity is capacity associated with a nominal 10°F TD, 25°F/-20°F SST application condition historically established to successfully size equipment and components to satisfy a heat load, net of all influences, in an application. Enter your legacy model number. Lookup New Equivalent Model. R = 208-230/1/60 62 = 5 Vintage * 10 SEER Size 036, 049 and 060 only. **10 SEER Size 060 only. Table 1: Unit Nameplate Model Number Identifier Unit Nameplate McQuay Model Number CKL18-1L ACU018ARAY CKL24-1L ACU024ARAY CKL30-1L ACU030ARAY CKL36-1L... Page 4: Introduction Replacement Parts substantial fines. model on 6 ton •Single circuit, 2-stage cooling mod-els are available from 7.5 to 10 ton. •Dual circuit, 2-stage cooling stage models are available from 7.5 to 15 ton. •EERs up to 11.3 with IEERs up to 13.0 •Staged Air Volume (SAV™) 2-speed indoor fan motor system automati-cally adjusts the indoor fan motorDaikin McQuay Model PDAE Product Nomenclature. Note: For Illustration purposes only. Not all options available with all models. Unit Type. P = PTAC. Product Identifier. PDAE = A/C PMES/EA Replacement. Design Series. 1 = A Design 1 2 = B Design 2 3 = C Design 3 4 = D Design 4 5 = E Design 5. Unit Size. 007 = 7,000 009 = 9,000 012 = 12,000 015 ...McQuay ALS250AS27-ER10 I need the manual and service literature, thanks!! Reply . 10-01-2013, 06:54 PM #2. freonrick. View Profile View Forum Posts ... The model number is AGS351DP27NN-ER10, the compressors are HSA205QY13YA, thanks!! Reply . Quick Navigation Chillers Open Forum Top. Site Areas; Settings; Private Messages;What is the HP and tonnage of carrier chiller model number 10xb14001701? - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... Trying to find the tonnage of this McQuay Chiller M: WSC087-BAABC ... Overview. Positive pressure design with R-134a refrigerant which has no ozone depletion potential and no phase- out schedule. Smallest footprint per ton in the industry to optimize equipment room space. The exclusive movable diffuser geometry design avoids the potential for a surge. Quiet compressor design with unique refrigerant injection ... You can determine the size in tons of your Ducane HVAC system by examining the model number on the data sticker at the side of the a/c condenser (outdoor unit). Look at the end of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU ...Upgrade your HVAC system and join the Rebel revolution - the ultimate solution for industry-leading performance and climate-controlled comfort. With Rebel's new 3-31 ton heat pump design, you can enjoy year-round heating and cooling, even in freezing temperatures as low as -10°F. Remove reliance on fossil fuel and capitalize on a smaller ...Coil choices include water cooling, water heating, steam, booster, evaporator and condenser. Our Daikin Hi-F (high-efficiency) fins maximize heat transfer with fewer fins to lower your initial cost. Our Daikin E-F (energy-efficient) fins save energy by reducing air pressure drop as much as 33% while also lowering fan brake horsepower requirements.Mcquay Chiller Model Numbers Manuals Ánd Service. This particular unit can be matched with a 3 to 4 ton condensing unit. This particular furnacé is 90 efficient so its BTU output would be.90 x 100,000 or 90,000 BTUs. This number indicatés a slight révision has occurred tó the model séries not requiring á series change.

First, find the model number on the unit. It should be on a sticker or plate somewhere on the front or side of the AC. Once you have the model number, locate the first two digits. These digits will tell you the approximate tonnage of the unit. For example, if the model number starts with 24, the AC is approximately 2 tons.

McQUAY CENTRIFUGAL OPERATING LOG. .23 McQUAY SERVICE PROGRAMS 24.17, 18 18 18 18 18 18 19 19 INTRODUCTION GENERAL DESCRIPTION The McQuay Model PEH Centrifugal Water Chillers are com-plete, self-contained, automatically controlled water chilling units. Each unit is completely assembled and factory tested prior to shipment.This McQuay model WMC Centrifugal water chiller is a complete, self-contained, automatically controlled, fluid-chilling unit featuring dual Oil-Free Centrifugal Magnetic Bearing technology. This used 2006 McQuay 290 Ton Water-Cooled Chiller is located in our facility in Dallas, Texas and is ready to ship to your location. NEVER CHANGE OIL IN YOUR CHILLER AGAIN!!! McQuay WMC: Brochure McQuay ...McQuay has a solution for your specific application. Contact your local McQuay sales office for computer selections of chillers to match your requirements. The following chart provides recommendations for the model choice for your application. Application McQuay Model Cooling, most hours at full load < 1200 tons ttons%PDF-1.6 %âãÏÓ 1371 0 obj > endobj 1386 0 obj >/Filter/FlateDecode/ID[2C57F1C273E3CA498FA7F38C6B63FC5F>]/Index[1371 126]/Info 1370 0 R/Length 97/Prev 1518284/Root ...For Assistance: Give A Missed Call: @ 9210188999 Call Our Customer Support: 011-40319300 / 1860 180 3900 or Write To Us at: [email protected] For Refrigeration Products:Ruby: 972-777-6574. Jamey: 214-755-8019. [email protected]. Our Location. Our main service facility is located in Dallas, Texas. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Surplus Group. 2121 Santa Anna Ave. Suite 100.McQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York Horizontal (Ceiling) Water Source Heat Pumps – Sizes 007-070 (1/2 to 6 Tons) Model CRH (Standard Range: 55°F to 110°F) Model CRW (Extended Range/Geothermal: 25°F to 110°F) More than 40 years ago, McQuay designed the firstInstall a tee fitting with a leak-tight removable cap in each tube near the sensor fitting. This facilitates connecting a manometer or pressure gauge if testing is required. Use different colored tubing for the duct pressure (HI) and reference pressure (LO) taps, or tag the tubes. McQuay recommends 1/8" ID tubing. McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors of

Mary grace bridges.

Villainess level 99 ep 2.

Daikin Applied RoofPak® RPS (15-140 Tons) Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak® applied rooftop systems the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, with capacities from 15 to 150 tons, they combine the lower ...Within the model number, there will be a two-digit, even number. This two-digit number multiplied by 1,0000 represents the BTU rating of the air conditioner. For example, if you find 18 in the model number, the BTU rating is 18,000 BTUs. And since 12,000 BTUs equals 1 ton, we can do the math and determine that the AC tonnage is …Modular construction from 20 to 130 tons. Controls flexibility—MicroTech® III controls for easy integration with the BAS of your choice. R-410A refrigerant allows higher efficiency (model SWP only) A self-contained AC unit from Daikin exceeds ASHRAE Standard 90.1 guidelines and provide higher operating efficiencies than alternative systems.Enfinity vertical floor-mounted water source heat pumps (WSHP), from 3/4 to 6 tons in left and right hand configurations, are designed for high efficiency, individually-zoned comfort control in office buildings, schools, hotels, assisted living dwellings, manufacturing facilities, and other commercial buildings.McQuay FMS Series Installation & Maintenance Data (24 pages) Vertical Water Source Heat Pump & Cooling Only Units. Brand: McQuay | Category: Heat Pump | Size: 0.74 MB. Table of Contents. Table of Contents. 1. Model Nomenclature. 2. Transportation and Shortage.Figure 1: Nomenclature (see Table 3 page 45 through page 49 for complete model number description) Figure 2: Model FCHH with Return Plenum Unit Type FC = Fan Coil FH = Cabinet Unit Heater Unit Configuration H= Horizontal Cabinet Type C = Cabinet R = Recessed H = Hideaway FC H C - 1 02 A Voltage A = 115/60/1 E = 208-230/60/1Enfinity console water source heat pumps (WSHP), from 1/2 to 1-1/2 tons, are designed for high-efficiency, individually-zoned comfort control in offices, schools, assisted living facilities, manufacturing buildings, and a variety of commercial applications. Using ozone-friendly R-410A refrigerant, Enfinity's quiet, high performance and ...This Daikin/McQuay 500 ton chiller /Type 134A refrigerant (Empty) is being sold for parts or repair. The unit has one bad head and is being sold as-is. The cooling capacity is 500 ton and it has a 3 phase power phase.Browse Model Number DX16SA0371, 16 SEER AC UNITARY 3 TON SINGLE STAGE in the Daikin North America LLC catalog including Model Number,Item Name,Description,Nominal Cooling Capacity,Sound Level,Compressor - Rated Load Amps,Compressor - Locked Rotor AmpDMAIC Model - The DMAIC model is commonly used in the Six Sigma process. Learn the ins and outs of the DMAIC model and how it applies to business optimization. Advertisement Proce... ….

Download 184 McQuay Heat Pump PDF manuals. User manuals, McQuay Heat Pump Operating guides and Service manuals.How Do I Read My AC Model Number? Let's look at a Trane brand air conditioner as an example. Capacity: Trane has used a number of different methods for encoding capacity information in the model number. It is commonly found in the first three digits - sometimes as BTUs and sometimes as tons. Example: SPCC-B504-A = 5.0 ton, or; TWS748A ...The McQuay RoofPak air handling unit arrives on the job site fully assembled and factory tested ready for start-up. An ... labeled and all wiring is color and number coded. A …burner model number, minimum/maximum input, maximum temperature rise, and minimum CFM. On units that utili ze the tandem scroll compressor design, each compressor includes an individual nameplate along with a nameplate identifying the tandem compressors. On units that utilize the tandem reciprocating design, eachPart Number: 331374601 Effective: March 2008 Supersedes: December 2007 Water-Cooled Centrifugal Chiller ... The McQuay Model WMC Centrifugal Water Chillers are complete, self-contained, automatically controlled, fluid-chilling units featuring oil-free, magnetic bearing compressors. Each unit is completely assembled andner on the main control box door. It includes the unit model number, serial number, unit part number, electrical character-istics, and refrigerant charge. Compressor Nameplate On units with a single compressor on each circuit, the com-pressor will include one compressor nameplate. On units that utilize the tandem compressor design, eachYou may be able to determine the tonnage of your HVAC unit by simply reading the manufacturer's label on your system's outdoor unit. However, most manufacturers don't list tonnage and instead, list BTUs. Converting BTUs to tonnage can be done by simply dividing the BTUs by 12,000. For example, if your HVAC system is 24,000 BTUs, its ...The Magnitude® centrifugal chiller delivers energy savings that building owners demand. Using direct drive technology, integral variable-frequency drives, and R-134a, R-513A, R-515B, or R-1233zd (E) refrigerant, Magnitude® is up to 40% more efficient than standard centrifugal chillers and can save up to $4 million over the life of the chiller.Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU's in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU's. A 2.5 ton system would have 30,000 BTU's. These are reflected in the model numbers near the middle and often followed by a letter. Mcquay model number tonnage, 1998 McQuay Air Cooled Liquid Chiller- 204 Ton. Model: ALS204AS12. S/N: 58G8128101. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 208 V, 881 amps, 60 Hz, 3 phase. (2) McQuay Screw Compressors, Models: SAL175RA13DA and SA175BA13DA, S/N's: 52ER7027-10 and, McQuay 5-ton vertical water source unit drawing too many amps; Cookie Consent ... It's a McQuay unit (model number W.FMS.3.060.E.Z.00.Z.00.AA.11.Z.Z.C.2) installed in a closet by our entryway. Thanks, Joe Reply . 08-13-2013, 03:55 PM #2. coolperfect. View Profile View Forum Posts, View and Download McQuay MWH011B manual online. Horizontal Water Source Heat Pumps And Cooling Only Unit. MWH011B heat pump pdf manual download. ... Heat Pump MODEL MWH030BR MWH040BR MWH050BR MWH060BR MWH070BR 13.2 14.6 18.5 22.4 NOMINAL COOLING CAPACITY Btu/h 29920 44870 49880 63160 76460 15.1 16.6 20.0 22.4 NOMINAL HEATING CAPACITY Btu/h ..., Manufacturer McQuay. Tonnage 500. Air or Water Water Cooled. Refrigerant R-134a. Voltage 460. Phase 3. Hz 60. Model Number WME0501SBSNA. Serial Number STNU180500038., View and Download McQuay ACU018ARAY installation and maintenance manual online. ACU Split System Air Conditioners 1-1/2 to 5 ton. ACU018ARAY air conditioner pdf manual download., Available from 300 to 1200 tons, single compressor centrifugal chillers offer excellent full-load and part-load performance for increased energy savings and an excellent life cycle return on your investment. Using R-134a or R513A refrigerant, these chillers easily integrate with building automation systems, are seismic compliant, quiet and have ..., Engineered HVAC Solutions for Alaska - Stinebaugh & Company, The entire "Model Number" blank on the nameplate reads: "YKKKKLH9-CVF". The unit is a centrifugal chiller, 460 volt, has a VFD drive, the compressor model is "YDHE-70VDD", and the serial number is "SASM-435150". ... Hello, I need to know the tonnage rating for a McQuay Model WSC087BAAA style E733329010 chiller. The SN is STNU020400172., The Magnitude® centrifugal chiller delivers energy savings that building owners demand. Using direct drive technology, integral variable-frequency drives, and R-134a, R-513A, R-515B, or R-1233zd (E) refrigerant, Magnitude® is up to 40% more efficient than standard centrifugal chillers and can save up to $4 million over the life of the chiller., Since 1980s, McQuay and its former name Westinghouse, were distributed by a local Government Registered E&M contracting company and successfully penetrated into the market of public utilities and private sectors. Number of water cooled and air cooled chillers were installed in Government buildings, hospitals, commercial and industry buildings., SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200, McQuay ALS250AS27-ER10 I need the manual and service literature, thanks!! Reply . 10-01-2013, 06:54 PM #2. freonrick. View Profile View Forum Posts ... The model number is AGS351DP27NN-ER10, the compressors are HSA205QY13YA, thanks!! Reply . Quick Navigation Chillers Open Forum Top. Site Areas; Settings; Private Messages;, SALES. [email protected]. 817-229-3171. North Texas Office: Dan @ 817-966-5350. South Texas Office: Mike @ 210-413-3333. This Used McQuay 75 Ton Air Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment., Browse Model Number DX16SA0371, 16 SEER AC UNITARY 3 TON SINGLE STAGE in the Daikin North America LLC catalog including Model Number,Item Name,Description,Nominal Cooling Capacity,Sound Level,Compressor - Rated Load Amps,Compressor - Locked Rotor Amp, All McQuay low and medium pressure central station air handling units (sizes 114 through 172) have factory installed, internally mounted motors and drives .. This means that ex­ …, A ton of air conditioning equals 12,000 BTU, and 24 divided by 12 equals 2, so the data plate below indicates the system is 2 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. If you are unsure whether you have found the right two ..., A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. If you are unsure whether you have found the right two ..., Quiet, 3-speed permanent split capacitor motor. High performance forward curved centrifugal fan wheels. Split design fan housings or single-piece fan housings with separate inlets for exceptional serviceability. Single power location for field wiring connections in unit elec-trical box., The Magnitude® centrifugal chiller delivers energy savings that building owners demand. Using direct drive technology, integral variable-frequency drives, and R-134a, R-513A, R-515B, or R-1233zd (E) refrigerant, Magnitude® is up to 40% more efficient than standard centrifugal chillers and can save up to $4 million over the life of the chiller., 15- and 20-Ton Packaged Ultra-High-Effi ciency Rooftop Performance Data (Gas or Electric Heat) Nominal Size (tons) 15 20 Effi ciency Ultra-High Ultra-High Model Number LCH/LGH 180U4M LCH/LGH 240U4M Blower Type MSAV - Belt Drive MSAV - Belt Drive Net Cooling Capacity (Btuh) 180,000 234,000 Cooling Stages (up to) 4 4 Nominal Supply Air (cfm ..., McQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C., Trane TTA180C series Installation Operation & Maintenance (32 pages) Split System Cooling Condensers 7 1/2 - 20 Tons. Brand: Trane | Category: Air Conditioner | Size: 2.63 MB. Table of Contents. Table of Contents. 3., AGZ 035A Installation, Operation And Maintenance Manual. 100 pages. AGR 070AS Operation Manual. 53 pages. WMC-B 145S Installation Manual. 100 pages. 5ACV 30 CR Installation Manual. 68 pages. AGZ 010BS Installation, Operation And Maintenance Manual., The Model 3 "is going to blow many, many minds." Tesla hopes to enter the hearts—and driveways—of millions of people around the world with the debut of its first mass-market electr..., 2. Locate the Serial Number on the tag. It probably just says "Serial," before the number. Decode the Carrier Serial Number - 9 and 10 Digits. OK, now here is how to read a Carrier AC serial number - or the number on a heat pump or furnace. 1. The first two numbers refer to the week of the year. 01 is the first week in January. 52 is ..., Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong Kong, Hetecho Engineers. Tilpat, Ghaziabad, Uttar Pradesh. View Number. Chvac Machinery Solutions Private Limited - Offering Mcquay Chiller, Capacity: 100-1500 TON at Rs 500000 in Ghaziabad, Uttar Pradesh. Get Water Chillers at lowest price | ID: 21748827133., Daikin McQuay Packaged System Nominal capacity 006 = 6 tons 007 = 7.5 tons 010 = 10 tons 012 = 12 tons Design vintage A = Vintage 1. Cooling efficiency. H = High (exceeds ASHRAE 90.1) Line voltage 2 = 208 volt power supply 3 = 230 volt power supply 4 = 460 volt power supply 5 = 575 volt power supply Heat medium Y = None (cooling only) G ..., consistent with the McQuay rooftop line. Expanded flexibility along with the availability of the state-of-the-art, MicroTech direct digital control (DDC) system on the RDS 800C and 802C makes the RDS unit the ideal selection in rooftop air handlers. Lower installation costs The McQuay RoofPak air handling unit arrives on the job site, A three-speed control switch with off position and wall plate is furnished for installation by the contractor in a standard 2 x 4-inch junction box. The speed switch can be wired to any three of the four motor taps to provide air delivery in three increments from 100% to 50% of rated airflow. Air discharge., More than most industries, fashion is preoccupied with youth. Yet the world is experiencing a rise in the number and proportion of older people. More than most industries, fashion ..., A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the data plate below indicates the system is 3 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 4 tons., vintage McQuay Commercial Packaged Rooftop Unit model MPS. In addition to an overall description of the unit, it ... It includes the unit model number, serial number, electrical characteristics, and refrigerant charge. ... Figure 4: Roof Curb Installation—MPS 30-35 Ton. McQuay IM 842 7 Mechanical Installation Figure 5: Curb Layout—MPS 30-35 ...