Kaba safe lock error codes

Apr 13, 2020 ... the Master code on a Kaba 525 Electronic Safe Lock. Also make sure to check your new code 2-3 times, before locking your safe door over ...

Kaba safe lock error codes. The model 52 is supplied with all basic functions for residential and commercial applications with the convenience of electronic locking. Alternatively, the T52 is available with time delay functions. 2 users. 6 digit access. Replaces mechanical Group I and Group II locks. Round or vertical housing.

If you have not read the section on “Dialing the X-09”, it is important that you do so before proceeding. SINGLE COMBINATION MODE In this mode the X-09 functions much like a standard combination lock. It will open any time the three-number combination is correctly dialed. 1. Dial left (CCW) until lock is “powered”.

Kaba Mas makes a range of high-security electronic safe locks from the company's factory in Lexington, Kentucky. A numeric code, entered using the buttons on the front of the lock, protects the contents of the safe from unauthorized access. You might want to reset your lock if someone learns your entry code.X-10 Type 1F Operating Instructions. X-10™ Type 1F High Security Electronic Lock – Operating Instructions. The X-10 uses sophisticated computer security and makes dialing much easier than that of traditional combination locksb The microprocessor in the lock recognizes a number as part of a combination when you change dialing directionb.Safe locks are designed to protect money, valuables, important documents, and sensitive goods from unauthorized access. dormakaba offers an unmatched portfolio of safe locks. dormakaba’s portfolio covers almost all government, banking, business, transit, and personal securing applications with high-security locks, electronic locks, and mechanical locks. dormakaba can look back on a 145-year ...9. Model Check Procedure: There is a simple test to verify if your lock is a model 6120 or a 6123. Press *8 . A model 6123 will emit 1 single beep followed by 3 beeps, followed by another series of beeps. A model 6120 will remain silent or emit 1 or 2 short beeps, depending on when it was manufactured. 10.Kaba Mas X-10 Accessory - 10" Conversion Kit. Since its founding in 1955, Lockmasters has been built on of distribution leadership, product innovation, discovery and education, Lockmasters has empowered an entire industry to realize what is possible, forever changing the way we think and interact with physical security.

1 Locate, drill and tap holes to mount the Lock Assembly to the inside of the safe door using the installation template provided 2 Mount the lock with the three US 1/4-20 screws The recommended torque for mounting screws on the Swing bolt lock is 30 in /lbs (3.4 N•m) (Figure 12).Kaba Mas Product Bulletin #29 - Auditcon 2 Series Slide Bolt Locks - High Security Locks for Secure Storage Units: Kaba Mas Product Bulletin-18: Kaba Mas Product Bulletin-3: Kaba Mas Product Bulletin-24: Kaba Mas Product Bulletin-30: Kaba Mas Product Bulletin-356800 Series Key Lock; Gun Safe Locks. AxisBlu™ Atlas; Model 6730, 6731, 6741; Spartan™ Titan™ No Reset Code Locks. Atlas; Group 2 Mechanical Safe Lock 6730/6731; Pedestrian Door Lock. S&G 2890C; Safe Locks. 8400-8500 Series; Audit 2.0; AxisBlu™ Model 6124, 6125; Model 6630, 6631, 6651; Model 6730, 6731, 6741; Spartan™ Titan™ Vault ...Whirlpool washers are known for their reliability and efficiency in cleaning clothes. However, like any other appliance, they can sometimes encounter issues that may result in erro...Kaba Access Control will repair or replace, at our discre- tion, E-Plex 2000 Locks found by Kaba Access Control analysis to be defective during this period. Our only liability, whether in tort or in con-... Page 17: Add/Modify A User Access Code G. ADD/MODIFY A USER ACCESS CODE • When users no longer need access to the lock, delete the User Code.Ensure that the safe door is open before starting the reset process. Connect the reset box to the lock's keypad. Enter the Super Master Reset code as per the lock's instruction manual. Confirm the reset when prompted by the lock. After the reset, reprogram the lock with a new master and user codes as needed.Step 7. With the safe's door still open, enter the new combination code and try turning the handle. If the handle turns, then the code entered is correct. If you cannot turn the handle, the new code was not saved, and the old combination code is still active. You have to repeat the process from step 3. If the door does not open after you have ...

Types of Hotel Safes. Electronic Safes: These are the most common type of hotel safes and use a digital keypad to enter a code. They are powered by batteries or electricity and are designed to be user-friendly and secure. Mechanical Safes: These safes use a combination lock or a key to open and are typically found in older hotels. While …Page 16: Electronic Locks 2.2.1 Door Locks Kaba Ilco locks are battery-operated units that are installed, without wiring, on each door to provide access control throughout the property. Each lock is controlled by a microprocessor with an internal clock that is synchronized with the FDU (see Section 2.6 - Time). Page 17: Remote Access ControllersUpdated. Troubleshooting Guides. Click on the link below to open or download the document you would like to view. Document. Description. Rev. Last Updated. T92797. Electric Hinges Trouble Shooting Guide.Product Summary. Our patent protected Kaba 20 system is the pinnacle of our high security cylinder range, offering four radially arranged pin tumbler rows comprising of up to 22 pins. The Kaba 20 system is highly respected by end user clients and is praised for its durability and functionality. With extensive permutation capacities Kaba 20 ...All locks are tested and certified according to EN 1300 and some additionally to the Swedish standard SS 3880. Below you will find more info on the electronic code locks from Insys, Kaba, La Gard, S&G and M-locks. Please contact us for more information and support about any high security lock. available models

Glamourcraft coupon code.

Electronic Pushbutton Lock, PIN access, 100 Access Codes, 1,000 Audit Events, cylindrical, mortise and exit trim, ANSI/BHMA Grade 1 certified. E-Plex 3200 Series. Electronic Pushbutton Lock, PIN access, 3,000 Access Codes, 30,000 Audit Events, narrow stile applications, retrofits various Adams Rite mortise locking devices.Dial the combination(s) to open the lock and then retract the bolt. Release the container locking bolts. Open the container. Remove the dust cover plate. Locate the lock on back cover pin on the back cover of the lock case. (See Figure 1.) Turn the dial to the left to extend the bolt.FREE SAFEMAN TIP ON HOW TO CHANGE CODE ON KABA T52 ELECTRONIC SAFE LOCK!If you need any help or advice on this lock, send me a message or e-mail [email protected] Code (ecc), protects your system from potential crashes and inadvertent changes. So how about it be a ram server? Worth or not? Receive Stories from @ranlily Learn...Step 7. With the safe's door still open, enter the new combination code and try turning the handle. If the handle turns, then the code entered is correct. If you cannot turn the handle, the new code was not saved, and the old combination code is still active. You have to repeat the process from step 3. If the door does not open after you have ...Whirlpool washers are known for their reliability and efficiency in cleaning clothes. However, like any other appliance, they can sometimes encounter issues that may result in erro...

How to operate an X-09 electromechanical lock. This high security lock is standard on all GSA Approved Security containers, safes, file cabinets and storage ...Kaba Mas offers a variety of tools to help with your project during the development phase. To ensure that your Kaba Mas solutions are being implemented properly, we have certified installers. Kaba Mas has also developed valuable support resources to assist you and quickly answer your questions.TROUBLESHOOTING. Follow. QAS-1845 Alternate Programing. The Lifetime Warranty. Does not Lock (NL) Unresponsive keypad (no sounds, no lights) or partial function. Double Beep, Does Not Open. Handle-Spin.Quick Reference Guide X-10. If at any time the dial remains stationary for more than 40 seconds, the lock will reset (LCD will go blank) requiring the operator to redial the entire combination or restart the operation. If at any time the dial remains stationary for more than 40 seconds, the lock will reset (LCD will go blank) requiring the ...The following are the problems represented by the number of yellow lights flashing: The yellow light flashes rapidly eight times when a keycard is used. The key could be expired; make a new key. The lock may be in electronic lock-out mode; use the ELO key and remove the lock-out. The yellow light flashes slowly 12 times when the keycard is used.Kaba SL525 Motorised Safe Lock Kaba SL525 Motorised Safe Lock ECB-S, EN 1300 level B, VdS class 2, VdS strike plate contact for IDS class C, CNPP a2p level B, UL Type 1 CODES: 1 Master code 2 Manager codes 18 User codes 1 Courier code Code Functions Selectable codBelow is a list of contact numbers for various dormakaba services: Customer Service: (800) 942-7263. Crane Revolving Doors: (800) 523-8483. Door Hardware and Glass Systems: (800) 999-6213. Hotels and Multihousing Systems: (844) 773-2669.Dual Custody Mode Both User 1 & User 2 combinations are required to open lock. Super Master Control A 6-digit code is used to reset lock to Factory Defaults [optional]. All functions are field programmable. A Wrong Try Lockout Penalty of 3 minutes will start after 5 wrong combinations are entered. ... Product Reviews for Kaba Mas Digital Safe ...When any display appears on the LCD, the lock is fully powered. When the lock is fully powered, the display will remain for 40 seconds. After 40 seconds of no dialing (or after very slow dialing), the LCD will go blank. After another 2 minutes, the lock is completely powered down. If the LCD goes blank while you are operating the lock, you must ...

How-to Activate a Cencon Gen 2 Lock from Factory Mode to FLM or Route Mode

Simplex Mechanical Pushbutton Locks eliminate problems and costs associated with issuing, controlling, and collecting keys and cards. The Simplex 1000 Series provides exterior access by combination, while allowing free egress. This mechanical lock, with knob option, eliminates the material and labor expense of battery replacements, has a single ...Jan 18, 2024 · Code Entry: Try entering your code. If the lock responds, your cleaning spree has paid off. Overcoming Incorrect Code Entry. Reset the Lock: Find the reset button (refer to your lock’s manual as this can vary). Press and hold it until you hear a beep or see a light flash. 1″ Deadbolt. Fits Doors With Thickness of 1⅜” – 2″. Powered by 4 standard AA batteries. Indoor/Outdoor, approved for uses ranging from -31 °F to 151 °F. Meets Florida windstorm specification and is certified compliant with the Florida Building Code (per FL 13061.1). UL Certified for use on fire-rated doors. (20-minute rating)Remove the back plate from the front lock housing by removing. the six back plate screws. 2. Lift the chamber linkage (A) off of the control shaft (B) by. prying up with a small flat blade screwdriver (see figure 1). 3. Remove the shaft bushing (C). 4. Remove the combination chamber (D) by removing the two.Your X-07 lock has been shipped pre-set in the Single Combination Mode with the combination set to 50-25-50. Practice opening the lock several times before you set a new combination. Your X-07 uses sophisticated computer security and makes dialing much easier than that of traditional combination locks.How do I reset my Kaba safe lock? Then press "#" and then "1.". The safe beeps as a green light flashes. Enter your six-digit combination. On some models, the default code is "502550.". Enter a new six-digit code. Re-enter your new code for the second time. Use your new code for later use because it replaces your old code right away.by Kaba. $ 812.24 USD. The KABA Simplex EE1000 line of Mechanical Keyless Pushbutton Door Locks is ideal for situations where key coded security is needed not only on one but two sides of a door. The 1000 series features auto locking design that comes standard with key coded entry or optional master key interface for superior access control on ...9. Model Check Procedure: There is a simple test to verify if your lock is a model 6120 or a 6123. Press *8 . A model 6123 will emit 1 single beep followed by 3 beeps, followed by another series of beeps. A model 6120 will remain silent or emit 1 or 2 short beeps, depending on when it was manufactured. 10.Contact. © dormakaba Group 2024 all rights reservedUnit locks are programmed with one resident code (change key). Each key made with one resident code can have up to 64 unique identity codes. InSync M and L Unit Locks. The M and L unit configurations provide true residential entry lock functionality. Each time the inside lever is rotated, the lock goes into a "toggled" condition which ...

Weather in anaheim january.

Majestic theater yakima.

The reset box is a device that allows you to revert the lock to its original ‘works mode.’. Here are the steps to follow: Ensure that the safe door is open before starting the reset process. Connect the reset box to the lock’s keypad. Enter the Super Master Reset code as per the lock’s instruction manual.1″ Deadbolt. Fits Doors With Thickness of 1⅜” – 2″. Powered by 4 standard AA batteries. Indoor/Outdoor, approved for uses ranging from -31 °F to 151 °F. Meets Florida windstorm specification and is certified compliant with the Florida Building Code (per FL 13061.1). UL Certified for use on fire-rated doors. (20-minute rating)Operating instructions 12.3 Locking of running carriage LAVeRI + LAVeRI-fS Check if the locking of running carriage is safely engaged. if necessary, check the locking play: manually close the sliding wing. Center the locking latch resp. the locking hook. Screw down the locking of running carriage.In many cases the lock may signal a correct code (double beep) but may not have enough power to open. It is recommended that the batteries should be replaced once annually. The Lagard Basic Lock contains a non-volatile memory chip and will retain all programming even with the batteries removed from the lock. CHANGING YOUR BATTERY. 1.The modular electronic safe lock can be networked or used as a single stand-alone unit. Axessor locks maintain up to 40 user codes and can be efficiently managed remotely. With the remote access function, administrators can …This video shows how to change the master code on the Kaba Mauer Combi B30 lock.Always change your code with the door OPEN and test the new code several time...dormakaba - countriesManualsLib has more than 89 Kaba Door locks manuals . Click on an alphabet below to see the full list of models starting with that letter: 1 5 7 A C D E I L P S T. Popular manuals. 48 pages. Simplex 1000 Series Installation Instructions Manual. 40 pages. EF 680E User Manual. 2 pages.The model 52 is supplied with all basic functions for residential and commercial applications with the convenience of electronic locking. Alternatively, the T52 is available with time delay functions. 2 users. 6 digit access. Replaces mechanical Group I and Group II locks. Round or vertical housing. The model 552 provides advanced features including: Time Window Access, Time Delay, Time Lock functions plus a time and date stamped audit trail. Appropriate to the needs of the customer, the locking periods can easily be set with the software and programmed to the lock via Smart Key. 99 users/400 record audit. 8 digit access combination. ….

Codes. Master (super master reset) 1 Manager; 1 User; Lock functions. Add/delete/enable/disable users (manager only) Silent alarm mode (manager only, optional upgrade) Dual-mode (optional upgrade) General functions. Low battery signal; Wrong-try penalty after 4 false codes; LED and beeper function indicators; 63 Audit events (optional upgrade ...To troubleshoot issues with the usage of the Dormakaba Saflok RT Plus, follow these steps: 1. Test the Mechanical Override Function: Verify the functionality of the mechanical override by inserting the key (L1) in the cylinder (D1) and turning it clockwise until it stops. Hold the key in the stopped position and turn the lever handle (A1) in ...Product Summary. The modular electronic safe lock Axessor is a lock system with up to 14 locks that can be operated both individually and in conjunction with several thousand lock systems. It can be used wherever organizational flexibility, fast response and increased security are required. Axessor IP may be configured remotely.The VingCard 2800 is an electronic locking system commonly used in hotels and other hospitality environments. The front desk system is crucial for encoding keycards and managing guest access. If you're experiencing issues with your VingCard 2800 Front Desk System, here's a general troubleshooting guide to help:Step 1: Insert the DF-59 control key into the combination change plug assembly (located on the back) and unscrew the cylinder by turning the key counterclockwise. Remove the combination change plug to gain access to the combination change sleeve. Step 2: Turn the outside knob once clockwise (all the way, until it stops) then release.December 2020 6 dormakaba/Kaba Mas® Cencon® ATM Security Lock - Bank Mode Training Booklet Display Prompts Found Only on Gen 2: G2 Indication during power-up of Gen2 lock firmware CEC At EC power up, alerts that Clock was reset (need clock set key) CLB Virtual Change Key for Swing and Motorized Dead Bolt CLS Clock Set operation is in process RLO Remote Lock Out; combination entry is preventedCencon S2000 without "Shunt". Without output signal (appropriate Smart Key & valid code entry) Spindle/Cable. For door thickness up to 55 mm. For door thickness up to 130 mm. For door thickness up to 250 mm. Accessories. Software Cencon 5® Single Server Software/License.The SafeLogic Basic is a very reliable and robust safe lock system ideal for most applications. The SafeLogic Basic features SECURAM's rugged stainless steel construction. ... Simple to Use and Reliable: Enter your 6 digit code and turn the safe... SR-BASIC-CH-601 $124.85. Add to Cart Compare. ... KABA-MAS X-10 LOCK PACKAGE - (NSN 5340-01-625 ... Kaba safe lock error codes, Plot No. S 20135, Road No. SW 301 G. 17268 Jebel Ali, United Arab Emirates. Phone: +971 4 8020400. Get in touch. The Electronic Combination Lock Code-Combi B - with dead bolt and mechanical redundancy for safes CEN III-V., The Saffire LX come with Bluetooth Low Energy (BLE) included. Using the dormakaba Mobile Access Solution, residents can conveniently use their mobile device with Saffire to access their residence, as well as perimeter, elevator, parking and other common areas. Available Models: Mortise - LX-M. Deadbolt - LX-D. Interconnected - LX-I., Product Summary. Paxos is the redundant, motorized lock for safes and vaults when it comes to providing maximum reliability, ease of use, programming and installation. Over a course of millions of operating hours, Paxos has proven technology and reliability time and time again. The next generation Paxos advance IP is the consistent and logical ..., Kaba Mas offers a variety of tools to help with your project during the development phase. To ensure that your Kaba Mas solutions are being implemented properly, we have certified installers. Kaba Mas has also developed valuable support resources to assist you and quickly answer your questions., Product Summary. The Basic Series offers standard functionality by combining operation comfort and reliability. Different Entry Devices - all in metal design - are available with a soft keypad or a foil keypad. According to the safe application, a deadbolt or a swingbolt locking system can be chosen. The patented swingbolt technology offers a ..., Quick Reference Guide X-10. If at any time the dial remains stationary for more than 40 seconds, the lock will reset (LCD will go blank) requiring the operator to redial the entire combination or restart the operation. If at any time the dial remains stationary for more than 40 seconds, the lock will reset (LCD will go blank) requiring the ..., No. Display text Type Res Comments and possible troubleshooting 3 AKI > 60 sec. active Inside radar longer than 60 sec. active and door remains open. Check that no moving objects are activating the radar. 5 AKA > 60 sec. active Outside radar longer than 60 sec. active and door remains open. Check that no moving objects are activating the radar., The lock may have been setup in dual mode, and is expecting a 2nd code to be entered. Enter a 2nd code; The lock may be an AuditGard 66e and is awaiting insertion of a user Dallas key. To test if the lock requires a Dallas key, hold down the last digit of any code. If the lock doesn't require a user Dallas key, two sets of double beeps will ..., The Kaba Mas CDX-10 consists of an X-10 high security style 1 lock, Federal Specifi cation FF-L-2740B, mounted on a deadbolt base plate. The base plate is surface-mounted to the inside face of the door. The deadbolt base plate has two essential features: First, it provides a means of latching the bolt in the retracted position., Especially suitable for class CEN III-V safes. The Combi B 30 is the follower of the popular Code Combi B. Apart from a complete reworked and user friendly input unit design the lock provides a significant increased range of functions. The integrated mechanic redundancy offers maximum reliability: by removing the rotary handle the hidden ..., Press enter once and manager 1 will be come up and say used. Press the right cursor key once and manager 2 will come up used, if code has been set. Repeat steps 7 &8 to change Manager 2 code. Press Information arrow symbol to come out of Manager 2 section and manager will be displayed. 11 for example. (15) Follow steps 7&8 to change user codes., 3802 Firmware Dual-Handed Swing Bolt Lock or Dead Bolt Super MaSter reSet (SMr)* • 8 Digit code – default code 5-5-5-5-5-5-5-5 [consistent with other LA GARD locks] • If the default code is not changed before Manager changes his or her code then the SMR option will be lost, unless hard reset of the lock is performed., The lock may have been setup in dual mode, and is expecting a 2nd code to be entered. Enter a 2nd code; The lock may be an AuditGard 66e and is awaiting insertion of a user Dallas key. To test if the lock requires a Dallas key, hold down the last digit of any code. If the lock doesn’t require a user Dallas key, two sets of double beeps will ..., All you need to do is to clean up the sensors a little bit and then try to open the door lock again. Hopefully, it will start working perfectly, and at this point, you won’t have to bother with more solutions. Reset the Kaba Door Lock. At this point, your best bet is to go forward with the reset procedure., Page 47 Notes... Page 48 Kaba Access Control 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: 800.849.8324 or 336.725.1331 Fax: 800.346.9640 or 336.725.3269 www.kabaaccess.com PKG2280 0111... View and Download Kaba Simplex 1000 Series installation instructions manual online. Simplex 1000 Series door locks pdf manual download., 2. The lock will prompt with "<‐rL", this is the indication that the lock has entered the relock mode. 3. Dial left several turns and the lock will display numbers with a left arrow. 4. Dial the first number of any valid combination, when the number is reached, stop dialing. If, Kaba Mas 749 W Short Street Lexington KY 40508 phone 859-253-4744 toll-free 877-KabaMas (522-2627) fax 859-255-2655 www.kaba-mas.com X-09.R0511.1000 The Kaba Safe Lock Division relies on product innovation to meet our markets' ever-changing needs for loss prevention and access control solutions., Kaba Safe Lock は、堅牢なセキュリティ機能と信頼性で知られています。 ただし、すべての高度な電子機器や機械機器と同様に、トラブルシューティングが必要な問題が発生する可能性があります。, Here’s a quick guide on performing the reset: Confirm that you have the super master reset code. Enter the code following the manufacturer’s instructions. Wait for the lock to cycle and confirm the reset completion. Re-establish user settings and test the lock functionality. , If you own a Whirlpool washer, you may have encountered error codes at some point during its operation. These error codes can be frustrating, but they serve an important purpose in..., Ensure that the safe door is open before starting the reset process. Connect the reset box to the lock’s keypad. Enter the Super Master Reset code as per the lock’s instruction manual. Confirm the reset when prompted by the lock. After the reset, reprogram the lock with a new master and user codes as needed. , Kaba Axessor® IP safe lock Functional Scope Code functions 4 hierarchy levels: 1 master, 4 managers, ... Code 45 and 46 can be selected for control of interior compartments Code 47optional time code Code 48/49 for lock disabling/enabling One shot codes for Group 4 Dual mode for group / user opening Optional dual manager mode for ..., Safe locks are designed to protect money, valuables, important documents, and sensitive goods from unauthorized access. dormakaba offers an unmatched portfolio of safe locks. dormakaba's portfolio covers almost all government, banking, business, transit, and personal securing applications with high-security locks, electronic locks, and mechanical locks. dormakaba can look back on a 145-year ..., The code being entered is not the correct code. A red light flash after you have entered the code and a failure to unlock means "access denied" or "invalid code". Applies To. OM500, OM2000, and/or OM Wireless. Additional Information., The Auditcon family of electronic locks was developed to address the security requirements of a broad range of financial, retail, commercial and industrial markets. The Auditcon 2 Series of safe locks offers housing styles and accessories to suit your individual needs. All models are available in either Round or Vertical housings., Apr 13, 2020 ... the Master code on a Kaba 525 Electronic Safe Lock. Also make sure to check your new code 2-3 times, before locking your safe door over ..., Sustainability. 04/26/2024, 17:31 CEST. Last Price. 484.00 CHF. Change. 0.00 CHF (0.00%) DOKA CH0011795959. The Ilco and Saflok product brands offer a complete selection of guest room locking and access management solutions for limited service properties, as well as deluxe destination resorts., Troubleshooting Tips. I lost the combination or keys to my safe. What should I do? For your protection, the most important aspect of this process is for us to verify the true ownership of the safe. Please go to the COMBINATION/KEY REQUEST section of this website and follow the instructions. You will be required to provide a notarized signature ..., X-10 Type 1F Operating Instructions. X-10™ Type 1F High Security Electronic Lock - Operating Instructions. The X-10 uses sophisticated computer security and makes dialing much easier than that of traditional combination locksb The microprocessor in the lock recognizes a number as part of a combination when you change dialing directionb., The Kaba Mas CDX-10 consists of a General Services Administration (GSA) approved; X-10 High-Security combination lock mounted on a deadbolt base plate. The base plate is surface mounted to the inside of the face of the door. The system provides a means to use a GSA approved combination lock to secure pedestrian doors on Secure Compartmented ..., Green and Red Together (Single Flash) then Red (Unsuccessful Initialization): This pattern suggests an issue with the lock initialization process. Try re-initializing the lock, ensuring that the process is completed without interruption. Green and Red Together (Single Flash for 6 Seconds) (Test Card): This indicates that a test card is being used., If you experience any issues with a Kaba X-10 lock or an S&G 2740B or 2937 lock, please contact our Technical Support department: Phone: 1-866-353-7233 Email: [email protected] Hours: Monday - Friday 9:00am - 5:00pm (EST) If you need assistance beyond our hours of operation, or if you are located outside of the USA, please contact ..., The Kaba Mas CDX-10 consists of an X-10 high security style 1 lock, Federal Specifi cation FF-L-2740B, mounted on a deadbolt base plate. The base plate is surface-mounted to the inside face of the door. The deadbolt base plate has two essential features: First, it provides a means of latching the bolt in the retracted position.